Study | Design | Session | Intervention | Variable | Participants | Age | Sex | Height | Mass | Task | Tools |
---|---|---|---|---|---|---|---|---|---|---|---|
MA. Feger et al. 2016 [27] | Descriptive laboratory | Single | Novel device | Pressure, COP, muscle activity | 10 CAI | 21.5 (3.1) | 3Â Male, 7Â Female | 166.0 (6.3) | 65.6 (10.4) | Walking | Pedar-x plantar pressure system (Novel Inc., St Paul MN, USA) with in-shoe insoles |
DM. Torp. 2021 [6] | Crossover | Single | Auditory and visual | COP, pressure | 19 physically active adults with CAI (7 male, 12 female | 23.95 ± 5.52 years | 7 male, 12 female | 168.87 ± 6.94 cm | 74.74 ± 15.41 kg | Single-limb static balance, step downs, lateral hops, and forward lunges | AccuSway Optimized force platform (Advanced Medical Technology, Inc), pedar-x, laser, FlexiForce Load Sensor (Tekscan, Inc., South Boston, MA). FlexiForce Quickstart Board, potentiometer (Tekscan, Inc), buzzer |
L. Donovan et al. 2016 [17] | Descriptive laboratory | Single | Auditory | Peak pressure, pressure time integral, contact area and time, muscle activity | 10 CAI | 21.5(3.1) | 3 male, 7 female | 166(6.3) | 65.6(10.4) | Walking | Pedar x, standard athletic shoe, force sensitive resistor, piezobuzzer,trimpot, electromyography |
DM. Torp 2019 [15] | Descriptive laboratory | single | Visual | Plantar pressure, COP | 26 CAI | 18–40(20.9 ± 2.4) | 11 male, 15 female | 170.2 ± 10.2 | 78.4 ± 22.1 | Walking | Pedar-X two pressure insoles connected to a wireless transmitter, standard, neutral athletic shoe,laser |
AM. Ifarraguerri 2019 [16] | Descriptive laboratory | single | Visual real-video | Medial forefoot peak pressure, plantar pressure, | 26 CAI | 20.9 ± 2.4 | 11 male, 15 female | 170.2 ± 10.2 | 78.4 ± 22.1 | Walking | Pedar-x, TV, camera, shoe |
KG. Migel (kinematic) 2021 [29] | Repeated measure | Single | Vibration | 3 dimensional joint kinematics during initial con- tact and loading response. | 19 CAI | 22.58 ± 4.18 | 10 male, 9 female | 170 ± 10.63 | 72.06 ± 14.78 | Walking | Custom made vibration feedback tool, small force sensing resistor (FSR) (Model 402, Interlink Electronics, Inc., Camarillo, CA, USA) |
DC. Mueler. 2020 [25] | Correlation | Lab-real world | Vibration | COP location, 3 dimensional ankle joint motion | 7 CAI | 23.28 ± 3.49 |  | 170.49 ± 10.02 | 73.26 ± 11.59 | Walking | 150 Hz Qualisys 8 camera motion analysis system, Qualisys Tracking Manager software. Force plates treadmill 1500 Hz., FSR |
KG. Migel 2021 [28] | Repeated measure, randomized crossover trial) | Lab-real world | Vibration | COP location | 19 CAI | 22.58 ± 4.18 | 10 male, 9 female | 170 ± 10.63 | 72.06 ± 14.78 | Walking | Two force plate treadmill, FSR |
JL. Workman. 2021 [26] | Repeated M | Lab-real world | Vibration | Loading rate, COP location | 19 CAI | 18–45 |  |  |  | Walking | Forceplate treadmill, vibfb tool, FSR |
J. Jang et al. 2021 [30] | Descriptive laboratory | Single | vibration | vGRF joint contact force | 10 CAI | 23.20 ± 4.19 |  | 168.69 ± 12.00 | 68.54 ± 12.03 | Walking | Force plate treadmill, FSR |
RM. Koldenhoven. 2021 [14] | Single-blinded randomized controlled trial | 8 sessions of impairment-based rehabilitation.2 week.retention in 10 minutes | Visual | 3 dimensional kinematics at the ankle, knee, and hip, electromyography amplitudes of 4 lower extremity muscles | 27 CAI (14 No biofeedback (control), 13 (experimental). |  |  |  |  | Walking | Dynamometer, 12 MOTION CAPTURE cameraS (VICON), EMG, lab shoes, pressure mat (MatScan TMPressure Mat, Tekscan Inc., Boston, MA, USA) |
MA. Feger et al. 2018 [31] | Quasi-experimental | 5 session in 5 to 10 days | Novel device | Plantar pressure, muscle activity | 16 CAI | 20 ± 2.6 | 6 male, 10 female | 171.3 ± 10.8 | 68.3 ± 15.9 | Walking | Plantar pressure treadmil, Pedar-x plantar pressure system (Novel Inc., St Paul MN), electromyography |
DM. Torp. 2022 [3] | Single-blind randomized controlled trial | 8-sessions of 30-minute in 2 weeks retain 1 week | Auditory | Pressure, force, COP, | 18 CAI randomly Control (n = 7) or experimental (n = 11) | 22.25 ± 3.33(control), 22.33 ± 2.50 | 2 male, 5 female (control), 4 male, 7 female (biofeedback) | 168.93 ± 14.03(control),166.92 ± 8.99 (biofeedback) | 80.48 ± 21.08c,74.20 ± 11.56 | Walking | Thin (14 × 25.4 × 0.203 mm) FlexiForce Load Sensor, potentiometer, buzzer |