Skip to main content

Table 1 Statistical evaluation of OHRM versus the chest-strap HR monitor

From: Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients

Activities

Hours collected

Coverage Δ ≤ 10 bpm (%)

Availability quality index > 0 (%)

MAE (bpm)

SEE (bpm)

Bias (bpm)

Healthy normal weight, BMI < 25

 Walking

20.6

95.4

99.2

1.8

4.7

− 0.2

 Running

7.1

96.0

99.5

1.7

6.6

− 0.7

 Cycling

11.3

98.4

99.9

0.8

2.6

−0.3

 Gym

60.6

92.5

98.6

2.9

9.3

−1.1

 Household

 Sedentary

21.0

98.0

99.9

1.3

5.5

−0.3

 Overall

120.5

94.7

99.1

2.2

7.4

−0.7

Healthy over-weight, BMI > 25

 Walking

6.4

97.1

99.5

1.2

3.2

0.1

 Running

2.0

98.8

99.9

0.8

2.8

−0.3

 Cycling

3.8

98.9

99.9

0.7

2.2

−0.2

 Gym

22.6

95.6

99.3

2.0

7.0

−0.7

 Household

 Sedentary

3.4

99.3

100.0

0.9

3.9

−0.1

 Overall

38.2

96.6

99.5

1.5

5.8

−0.5

Pregnant

 Walking

9.6

93.7

98.9

2.4

6.1

−0.1

 Running

 Cycling

3.4

99.9

100.0

0.3

1.0

0.1

 Gym

3.4

86.4

97.6

3.4

7.2

−2.0

 Household

9.6

86.0

98.4

4.2

7.3

0.7

 Sedentary

1.7

97.9

100.0

1.1

2.7

−0.6

 Overall

27.7

91.1

98.8

2.8

6.2

−0.1

CAD

 Walking

2.6

96.9

99.9

1.7

4.2

1.0

 Running

 Cycling

2.1

85.6

98.5

4.4

7.1

2.6

 Gym

0.8

95.1

99.0

2.7

4.2

0.7

 Household

3.5

95.2

99.4

2.2

4.9

0.4

 Sedentary

1.4

99.7

100.0

0.8

1.6

0.1

 Overall

10.3

94.2

99.4

2.4

5.0

1.0

All

 Walking

49.9

94.6

99.0

2.0

5.2

−0.0

 Running

43.6

95.2

99.0

2.0

7.2

−0.5

 Cycling

93.4

96.0

99.5

1.7

5.3

−0.4

 Gym

67.5

92.2

98.6

3.0

9.5

−1.2

 Household

67.6

94.7

99.6

2.3

5.0

−0.4

 Sedentary

49.0

98.4

99.8

1.2

5.7

−0.4

 Overall

371.1

95.1

99.3

1.4

6.5

−0.5

  1. OHRM Optical Heart Rate Monitor, MAE Mean Absolute Error, SEE Standard Error of the Estimate, CAD Coronary Artery Disease