Skip to main content

Table 1 Tests to investigate the effect of the increase of power during cycle ergometer tests (published on pages 156–171 in [21])

From: The origin of the maximal lactate steady state (MLSS)

Test

Starting Power

Power increment

Step duration

Power increase per unit of time

Typical usage of test

A

50 W

50 W

2 min

25.0 W.min− 1

Rowers and cyclists

B

50 W

50 W

3 min

16.7 W.min− 1

Commonly used in Germany

C

25 W

25 W

2 min

12.5 W.min− 1

Untrained participants, children, patients

D

70, 100 or 130 W

30 W

5 min

6 W.min− 1

Only used for this experiment