Skip to main content
  • Research article
  • Open access
  • Published:

Vibroarthrographic analysis of patellofemoral joint arthrokinematics during squats with increasing external loads

Abstract

Background

The patellofemoral joint (PFJ) provides extremely low kinetic friction, which results in optimal arthrokinematic motion quality. Previous research showed that these friction-reducing properties may be diminished due to the increase in articular contact forces. However, this phenomenon has not been analyzed in vivo during functional daily-living activities. The aim of this study was the vibroarthrographic assessment of changes in PFJ arthrokinematics during squats with variated loads.

Methods

114 knees from 57 asymptomatic subjects (23 females and 34 males) whose ages ranged from 19 to 26 years were enrolled in this study. Participants were asked to perform 3 trials: 4 repetitions of bodyweight squats (L0), 4 repetitions of 10 kg barbell back loaded squats (L10), 4 repetitions of 20 kg barbell back loaded squats (L20). During the unloaded and loaded (L10, L20) squats, vibroarthrographic signals were collected using an accelerometer placed on the patella and were described by the following parameters: variation of mean square (VMS), mean range (R4), and power spectral density for frequency of 50–250 Hz (P1) and 250–450 Hz (P2).

Results

Obtained results showed that the lowest values were noted in the unloaded condition and that the increased applied loads had a significant concomitant increase in all the aforementioned parameters bilaterally (p < 0.05).

Conclusion

This phenomenon indicates that the application of increasing knee loads during squats corresponds to higher intensity of vibroacoustic emission, which might be related to higher contact stress and kinetic friction as well as diminished arthrokinematic motion quality.

Peer Review reports

Background

The knee is one of the most loaded joints within the human organism which results in its considerable susceptibility to injuries and an increased risk of early degeneration of the articular surface [1, 2]. The patellofemoral joint (PFJ) plays a key role in the knee extensor mechanism since the patella, being the largest sesamoid bone, increases the length of the lever arm of the patellar tendon, which improves the quadriceps strength by 30–50% [3]. Additionally, the patella acts as a bony shield for the anterior trochlea and due to its interposed position in the extensor apparatus, protects against excessive friction between the quadriceps tendon and the femoral condyles [4]. An indication that the PFJ adapts to considerable loading is the thickness of the hyaline cartilage. It may reach 6–7 mm thick at the central part of patella, which constitutes the greatest thickness among synovial joints of the human musculoskeletal system [5, 6].

Physiological hyaline cartilage along with synovial fluid remarkably decreases the coefficient of kinetic friction, which determines efficiency of the knee extensor apparatus and helps protect against high compressive loads [7]. Using computer models or cadaveric specimens, researchers have shown that smooth and lubricated articular surfaces provide an extremely low level of friction, which fluctuates around 0.002 μ and 0.02 μ, depending on testing conditions [8, 9]. Within in vivo conditions this phenomenon is clearly visible in the evaluation of joint motion quality via vibroarthrography (VAG), a method based on the analysis of micro vibrations generated during relative movement of articular surfaces [10, 11]. This research has shown that young and healthy joints provide optimal, smooth and practically vibration free arthrokinematics [12, 13]. Using VAG, it was found that the there are many confounders of friction related to the qualitative aspects of arthrokinematics, including age-related alterations and degenerative changes within synovial joint environment, which directly translate into quicker degeneration of joint surfaces [14, 15].

It has been previously shown that VAG possess not only high accuracy and specificity when differentiating synovial joints’ deteriorations with various biomechanical and morphological origins, but also is sensitive for identifying the changes in arthrokinematics related to the level of the joint load at the end of a performed task [16,17,18,19,20]. From an arthrology perspective, this finding seems to be particularly important, because the load on articular surfaces is one of the most essential factors affecting the level of kinetic friction and joint wear [7, 21]. Meanwhile, most of the previously presented research associated with analysis of load impact on articular friction and contact stress has been based on mathematical modelling or ex vivo analysis, which constitutes a considerable limitation in their clinical application [22,23,24,25,26,27,28]. Thus, it seems that a noninvasive method, such as vibroarthrography, might provide a new perspective on PFJ arthrokinematics analyzed in vivo. Furthermore, as it was previously postulated, the subsequent VAG analyses should consider the influence of the load level on knee arthrokinematics during functional closed kinetic chain activities [19]. In comparison to analyses of open chain activities, the closed kinetic chain provides a better reproduction of the character of the PFJ in daily activities [23, 29, 30].

Hence, the objective of this study was to use vibroarthrographically assess the impact of load on PFJ arthrokinematics, analyzed in vivo during the squat motion. It was hypothesized that the level of vibroacoustic emission would be considerably higher during squats with increasing loads when compared to unloaded squats. We assume that the above-mentioned load-associated increase of vibroacoustic emission might be largely driven by the increase of kinetic friction and contact stress within the PFJ. The results of this study might aid clinicians’ understanding of the relationship between the level of articular surfaces compressive loads and qualitative aspects of arthrokinematics considered as friction-reducing properties of diarthrosis. Furthermore, these results could broaden knowledge related to the joint biotribology, and might benefit clinicians, because the squat has long been a basic element of strength training among athletes, as well as is various rehabilitative protocols [31,32,33,34]. Because PFJ disorders are commonly encountered in sports and rehabilitation, better recognition of biomechanical behavior of the PFJ during loaded and unloaded movements is essential in order to treat it effectively [4].

Methods

Participants

A convenience sample of asymptomatic volunteers was recruited from students of the Faculty of Physical Education and Physiotherapy of Opole University of Technology, Poland. To be included in this study, the participants were expected to be able to easily perform a series of squats with external loads of 10 kg and 20 kg. The external load of 10 kg constituted approximately 13% of body weight (BW) for men and 18% for women, whereas the percentage values for men and women doubled respectively for the external load of 20 kg. Additionally, the inclusion criteria included only participants with moderate physical activity level, according to the International Physical Activity Questionnaire (long form) [35, 36]. Moreover, only individuals with no history of knee disorder or other diagnosed injury or pathology within the lower extremity were included in the study group. The clinical evaluation of the analyzed group was based on both anamnesis (participant’s self-reported medical history) and physical examination performed by a senior physiotherapist, but without radiological exclusion of the cartilage pathologies. Finally, 114 healthy knee joints from 57 volunteers (23 females and 34 males) aged 19 to 26 years were enrolled in the study. Age, gender and anthropometric data in the analyzed volunteers are given in Table 1.

Table 1 Subject demographics (mean ± standard deviation)

Assessment of arthrokinematic motion quality

Based on previous studies, assessment of the PFJ arthrokinematic motion quality was performed with an accelerometer sensor placed 1 cm above the apex of the patella [11, 20, 37].

This measurement was performed during both unloaded and loaded squat movements. In total, participants were asked to perform 3 trials: (i) 4 repetitions of bodyweight squats (L0); (ii) 4 repetitions of 10 kg barbell back loaded squats (L10); (iii) 4 repetitions of 20 kg barbell back loaded squats (L20), with one-minute rest between each test. The order of the trials was randomly selected. In the unloaded trials, the squats were performed with the hands placed behind the head, while loaded trials used barbells of 10 kg and 20 kg (Fig. 1). In all these conditions, subjects were instructed to execute the squat from a neutral position (approximately 0° of knee flexion) to the depth of approximately 90° of knee flexion while maintaining heel contact with the floor. The constant velocities of flexion/extension movements were kept at 48 beats per minute with a metronome and the angle of the knee joint was measured using an electrogoniometer. Each squat test lasted 10 s, during which four cycles of squats were performed. Before data collection, each subject performed the squat maneuver within the protocol guidelines. Verbal feedback regarding both the depth and duration of the movement was provided after each training squat. The trials were repeated if the requirements were not fulfilled. An average of 4 attempts were required to obtain the 3 acceptable trials.

Fig. 1
figure 1

Participant during assessment (10 kg load)

The VAG signals were collected using an acceleration sensor, Brüel & Kjær model 4513B-002, with a multi-channel Nexus conditioning amplifier (Brüel & Kjær Sound & Vibration Measurement A/S, Denmark). Data were recorded at a sampling frequency of 10 kHz and then filtered using a fourth-order zero-phase Butterworth band-pass digital filter with cutoff frequencies between 50 Hz and 1000 Hz. The variability of the VAG signal in the time domain was assessed by computing the following parameters [37, 38]:

  1. 1)

    the mean-squared values of an obtained signal in fixed-duration segments of 5 ms each and then computing the variance of the values of the parameter over the entire duration of the signal (VMS) [39];

  2. 2)

    signal amplitude was calculated as the difference between the mean of the four most prominent peaks and the mean of the four most prominent troughs of the VAG signal (R4).

The frequency characteristics of the VAG signal were examined by a short-time Fourier transform analysis. The short-time spectra were obtained by computing the discrete Fourier transform of segments, 150 samples each, Hanning window, and 100 samples overlap of each segment. The spectral activity was analyzed by summing spectral power of the VAG signal in two bands: 50–250 Hz (P1) and 250–450 Hz (P2) [18, 37,38,39,40].

Statistical analysis

Normality of the distribution was assessed with the Shapiro-Wilk test. Because of a skewed distribution of VMS, R4, P1, and P2 parameter values, they were analyzed using a logarithmic transformation. Statistical significance of changes between assessment conditions (load level 0, 10 and 20 kg) was performed with one-way analysis of variance (ANOVA) with repeated measures, and then the Tukey’s honest significant difference (HSD) test for post-hoc comparisons. Differences in values of VAG parameters between left and right lower limbs were evaluated by dependent t-test for paired samples. For examination of correlations between analyzed variables, Pearson r tests were performed. The level of significance was set at p < 0.05. Statistical analyses were performed using Statistica version 10 (TIBCO Software Inc., Palo Alto, CA).

Results

Calculated values of analyzed VAG parameters (VMS, R4, P1 and P2), expressed as median and variance values are presented in Fig. 2 and Table 2. Moreover, for an additional expression of the VAG signals characteristics, representative plots of the vibroarthrographic registered time-series, specific for each load-related condition (L0, L10 and L20) are shown in Fig. 3. The plots contain acquired signal course expressed in volts (blue solid line, left y scale) and registered position of the joint (ROM) via electrogoniometer expressed in degrees (green dotted line, right y scale).

Fig. 2
figure 2

Values of vibroarthrographic parameters in the conditions analyzed (blue round marks, left limb; red square marks, right limb)

Table 2 Parameters of vibroarthrographic signals under different loads
Fig. 3
figure 3

The course of representative vibroarthrographic signals for conditions (a) with no load (b) with 10 kg load (c) with 20 kg load

The performed ANOVA revealed that there was a significant main effect of the applied load on values of each analyzed parameter, similar in both lower limbs. For the left limb the results were as follows: F = 11.69, p < 0.001; F = 15.30, p < 0.001; F = 16.70, p < 0.001; F = 16.64; p < 0.001, for VMS, R4, P1 and P2, respectively, and analogously for the right limb: F = 17.94, p < 0.001; F = 17.75, p < 0.001; F = 18.35; p < 0.001; F = 19.02. p < 0.001. Subsequently, using the post-hoc test we identified that the rising level of the applied load has a significant impact on increase of all VAG parameters, in both lower limbs (Fig. 2 and Table 2). The lowest values of VMS, R4, P1 and P2 parameters were noted during motion without additional load (L0). These values reflect the characteristics of the signals course typical for this condition, when signals possessed low amplitude and variability, only with small, occasional peaks (Fig. 3a). Application of 10 kg load (L10) resulted in a statistically significant increase of all parameters (Table 2). It is also seen in Fig. 3b is that the motion with additional load generated signals with higher amplitude and variability, as compared to the L0 assessment. However, the highest values of VMS, R4, P1 and P2 parameters were observed in L20 condition, which were significantly higher than in the L10 condition, except comparison of the left limb VMS (Fig. 2 and Table 2). In this situation, when movements were performed under 20 kg load, the VAG signals possessed a more complex course with high peaks, repeatable in each cycle of motion (Fig. 3c). It should be also noted, that when compared bilaterally, there were no VAG differences, in each load condition.

In our study we also analyzed the relationships between values obtained in the left and right lower limbs (Table 3). Statistical analysis showed the presence of moderate positive correlations, especially in the P1 parameter, for which interactions were significant in all load-related conditions. Nevertheless, for VMS, R4 and P2 correlations have been also established, but only in the L10 and L20 assessments. Moreover, there were some dependencies in all VAG values when L0 was compared with L10, and L10 with L20 trials (Table 4).

Table 3 Values of correlation coefficient between parameters of vibroarthrographic signals recorded for left and right lower limbs
Table 4 Values of correlation coefficient between parameters of vibroarthrographic signals in different load-related conditions

Discussion

Following previous publications, our experiment assumed that the intensity of acquired vibroacoustic emission waves is closely associated with the kinetic friction and represents friction-induced vibrations generated by relative sliding and rolling of adjacent articular surfaces. From biomechanical and tribological points of view the ability of the articular surfaces to move smoothly against each other with low frictional noise indicates optimal arthrokinematic motion related with low kinetic friction, and as a result contributes to slow wear of cartilage [20]. The presented findings of this study confirm that during a knee flexion-extension movement with the load of the body weight, the PFJ arthrokinematic motion possesses low-vibration characteristics, despite relatively high values of articular surface load, typical for this analyzed condition. It has been experimentally proven via cadaveric and mathematical models that the contact forces of the PFJ articular surfaces while performing a squat may even reach 3–3.5 kN and the peak contact pressure equals ~ 8–9 MPa at 90° of knee flexion, which corresponds to multifold values of human body weight [30, 31, 41]. However, due to the friction-reducing properties of synovial joints, the coefficient of friction, which is defined as the ratio between strength required to generate gliding motility and pressure force of the body towards a particular surface, is still very low in the mentioned condition. It fluctuates around 0.03 μ, which is only slightly higher than coefficient of friction values typical for unloaded PFJ motion [42,43,44]. In our study this phenomenon is observed as relatively smooth and flat VAG signals, representing low vibroacoustic emission. Both variability (VMS) and amplitude (R4) of representative signals are characterized by low values. Especially the low values of the R4 parameter that indicate a lack of repetitive large peaks, whose presence often corresponds with macroscopic joint cartilage abnormalities or significant maltracking of articular surfaces [18, 38]. In turn, low spectral activity analyzed by summing spectral power of the VAG signal in two bands: 50–250 Hz (P1) and 250–450 Hz (P2) seems to be related with intact integrity of the superficial layer of hyaline cartilage and an efficient lubrication mechanism [37, 45].

Nonetheless, in the present study we predominantly focused on the impact of the external load on the quality of PFJ arthrokinematic motion. As expected, the PFJ frictional noise raised near-linearly with increasing levels of external load. The application of 10 kg external load resulted in an average 3-fold higher variability of recorded signal (VMS) and an average ~ 1.5-fold increase of amplitude and spectral activity (R4, P1 and P2). Furthermore, the squats performed with the 20 kg load were characterized by further, analogous increase of the VAG signal variability/amplitude and higher, 2.5-fold increase of spectral power in band 50–450 Hz, when compared with the 10 kg load. Similar results have been presented by Andersen et al. [19], who also found divergences between different loads for all VAG parameters. However, this previous study was based on an open kinetic chain analysis and the applied loads (up to 5 kg) were lower than the loads analyzed in the current study, which are more typical for different activities of daily living and sports. Moreover, although the absolute values between studies differed as a result of disparate parameters’ settings being used, similar tendencies have been observed.

Research has previously reported that squatting with an external load results in significantly greater patellofemoral joint reaction force and stress compared to an unloaded squat, and that the increase is proportional to the applied load [41]. Authors showed that a squat performed under a 35% of body weight external load yielded a 44% increase in PFJ stress across all knee flexion angles, with a peak patellofemoral contact stress of 13.06 MPa at 90° of the knee flexion, whereas when unloaded, the peak patellofemoral joint contact stress equaled 9.06 MPa. Such elevated values of contact stress might cause very high frictional shear stress during gliding motion of the patella, which consequently dramatically increases kinetic friction and related frictional noise [44]. It should be also noted that the observed increase of VAG signal parameters might be the result of load-related decline in lubrication efficiency. Although many different lubrication mechanisms have been proposed, it is becoming increasingly accepted that mainly a fluid film lubrication is responsible for the low friction in synovial joints, especially at high loads [46, 47]. Fluid film lubrication involves a thin synovia film that provides separation of the joint surfaces. Synovia being squeezed out of cartilage into the joint space as loading increases creates a thicker layer of film. Therefore, a decreased coefficient of friction with increased contact stress has been reported in many studies [48]. This observation may explain why the results reported by Ladly et al. [49] indicated that a 3 pound (1.4 kg) external loading of the patellofemoral joint has an insignificant effect on VAG signal power. Nonetheless, it is generally accepted that when the contact stress reaches a medium level (4–8 MPa), the velocity of fluid exuded from the cartilage reaches its limit and there is a concomitant increase in the coefficient of friction (frictional noise) thereby, increasing contact stresses [44].

Since all participants used in this study were subjected to the same level of load, we were also able to assess intra-group relationships between the changes in characteristics of VAG signal courses under the influence of applied load and the anthropological data of the analyzed cohort. We expected some dependencies, especially between the body weight and the VAG signal values, because contact stress (considered as the main determinant of observed changes) is a parameter that reflects distribution of load and strongly depends on the area of contact between articular surfaces. However, there were no statistically significant correlation between body weight and values of VAG signal parameters. Nevertheless, weak but statistically significant correlations were noted for all the considered parameters for trials L0 and L10 as well as trials L10 and L20. This shows that subjects who had a low level of vibroacoustic emission during the bodyweight squats also obtained a low level during the loaded conditions. Thereafter, we discovered weak and moderate positive dependencies in values of all VAG parameters between the left and right lower limbs, but only for the loaded trials. Hence, there is an assumption that occurrence of the mentioned dependencies might indicate the presence of ontogenetic conditionings, associated with the friction-reducing properties of synovial joint environment and different levels of load tolerance. It is, however, a complex phenomenon that requires further extensive research.

In the light of findings reported in the current investigation, there are several limitations that should be noted. Consideration should be given that the conducted analyses were limited to asymptomatic young and agile subjects, who were performed squats with different relative external loads. So, although the present study provides crucial insights into the PFJ function during squatting with and without loads, caution should be exercised in extrapolating these data to older patient populations or those suffering from anterior knee pain syndrome. Moreover, the inclusion/exclusion criteria were based on a medical interview, but not confirmed by advanced imaging procedures. Therefore, we cannot exclude that knees of some subjects revealed minor asymptomatic cartilage changes which could have affected our results. Another potential limitation is the fact that the VAG is a method of indirect arthrokinematic analysis focused on acquisition of the vibroacoustic signal using single skin-mounted accelerometer. Therefore, it should be clearly emphasized that the presented method allows for observation of only the effect of the kinetic friction phenomenon in the form of frictional noise which holds a multicomponent character. Moreover, it should be considered, that the accelerometer (despite the application of optimal localization) might detect the vibrations not only from the PFJ but also from tibiofemoral joint or other tissues [50]. However, the mechanical properties of synovial joints related to the friction and wear cannot be directly measured in vivo. Thus, it is generally accepted that the VAG method, despite some limitations, might provide sufficient, clinically meaningful information about the function and biotribological changes in whole articular environment.

Accordingly, the presented results are clinically applicable, because weight-bearing exercises, such as the squat, are frequently used during rehabilitation and are specific to many activities of daily living and sport activities. The ability to understand how friction related aspects of PFJ arthrokinematics vary among weight-bearing exercises with different loads will allow clinicians and trainers to prescribe safer and more effective rehabilitation treatments for patients and athletes during training. This is a particularly significant issue because excessive joint friction has been linked to articular cartilage degradation and may contribute to premature wear and knee pathologies (e.g. chondromalacia or osteoarthritis).

Conclusions

The study constitutes a significant insight into the behavior of knee joint under external load conditions, specific to many functional activities. The presented results have shown that the application of increasing knee loads during squats corresponds to higher intensity of vibroacoustic emission, which might be related to higher contact stress and kinetic friction. However, it should be emphasized that these results are valid for asymptomatic healthy and young subjects.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

PFJ:

Patellofemoral joint

VAG:

Vibroarthrography

References

  1. Clark AL. Osteoarthritis: what we have been missing in the patellofemoral joint. Exerc Sport Sci Rev. 2008;36(1):30–7. https://doi.org/10.1097/jes.0b013e31815e4217.

    Article  PubMed  Google Scholar 

  2. Musumeci G. Functional anatomy in knee osteoarthritis: patellofemoral joint vs. tibiofemoral joint. J Funct Morphol Kinesiol. 2017;2(1):8. https://doi.org/10.3390/jfmk2010008.

    Article  Google Scholar 

  3. Friedman LGM, White MS, Carroll PF, Macalena JA, Arendt EA, Ellerman JM, et al. Arthroscopy correlation inthe patellofemoral joint. Sports Med Arthrosc Rev. 2017;25(4):227–36. https://doi.org/10.1097/JSA.0000000000000171.

    Article  PubMed  Google Scholar 

  4. Loudon JK. Biomechanics and pathomechanics of the patellofemoral joint. Int J Sports Phys Ther. 2016;11(6):820–30.

    PubMed  PubMed Central  Google Scholar 

  5. Koh JL, Stewart C. Patellar instability. Orthop Clin North Am. 2015;46(1):147–57. https://doi.org/10.1016/j.ocl.2014.09.011.

    Article  PubMed  Google Scholar 

  6. Sherman SL, Plackis AC, Nuelle CW. Patellofemoral anatomy and biomechanics. Clin Sports Med. 2014;33:389–401. https://doi.org/10.1016/j.csm.2014.03.008.

    Article  PubMed  Google Scholar 

  7. Jay GD, Waller KA. The biology of lubricin: near frictionless joint motion. Matrix Biol. 2014;39:17–24. https://doi.org/10.1016/j.matbio.2014.08.008.

    Article  CAS  Google Scholar 

  8. Daniel M. Boundary cartilage lubrication: review of current concepts. Wien Med Wochenschr. 2014;164:88–94. https://doi.org/10.1007/s10354-013-0240-2.

    Article  PubMed  Google Scholar 

  9. Krishnan R, Kopacz M, Ateshian GA. Experimental verification of the role of interstitial fluid pressurization in cartilage lubrication. J Orthop Res. 2004;22:565–70. https://doi.org/10.1016/j.orthres.2003.07.002.

    Article  PubMed  PubMed Central  Google Scholar 

  10. Rangayyan RM, Wu YF. Screening of knee-joint vibroarthrographic signals using statistical parameters and radial basis functions. Med Biol Eng Comput. 2008;46(3):223–32. https://doi.org/10.1007/s11517-007-0278-7.

    Article  PubMed  Google Scholar 

  11. Bączkowicz D, Kręcisz K. Vibroarthrography in the evaluation of musculoskeletal system – a pilot study. Ortop Traumatol Rehabil. 2013;15(5):407–16. https://doi.org/10.5604/15093492.1084242.

    Article  PubMed  Google Scholar 

  12. Wu Y, Chen P, Luo X, et al. Quantification of knee vibroarthrographic signal irregularity associated with patellofemoral joint cartilage pathology based on entropy and envelope amplitude measures. Comput Methods Prog Biomed. 2016;130:1–12. https://doi.org/10.1016/j.cmpb.2016.03.021.

    Article  Google Scholar 

  13. Bączkowicz D, Majorczyk E, Kręcisz K. Age-related impairment of quality of joint motion in vibroarthrographic signal analysis. Biomed Res Int. 2015;2015:591707. https://doi.org/10.1155/2015/591707.

    Article  PubMed  PubMed Central  Google Scholar 

  14. Kim KS, Seo JH, Kang JU, Song CG. An enhanced algorithm for knee joint sound classification using feature extraction based on time-frequency analysis. Comput Methods Prog Biomed. 2009;94(2):198–206. https://doi.org/10.1016/j.cmpb.2008.12.012.

    Article  Google Scholar 

  15. Yang S, Cai S, Zheng F, Wu Y, Liu K, Wu M, et al. Representation of fluctuation features in pathological knee joint vibroarthrographic signals using kernel density modeling method. Med Eng Phys. 2014;36(10):1305–11. https://doi.org/10.1016/j.medengphy.2014.07.008.

    Article  PubMed  Google Scholar 

  16. Tanaka N, Hoshiyama M. Vibroarthrography in patients with knee arthropathy. J Back Musculoskelet Rehabil. 2012;25(2):117–22. https://doi.org/10.3233/BMR-2012-0319.

    Article  PubMed  Google Scholar 

  17. Nalband S, Sundar A, Prince AA, Agarwal A. Feature selection and classification methodology for the detection of knee-joint disorders. Comput Methods Prog Biomed. 2016;127:94–104. https://doi.org/10.1016/j.cmpb.2016.01.020.

    Article  Google Scholar 

  18. Kręcisz K, Bączkowicz D. Analysis and multiclass classification of pathological knee joints using vibroarthrographic signals. Comput Methods Prog Biomed. 2018;154:37–4. https://doi.org/10.1016/j.cmpb.2017.10.027.

    Article  Google Scholar 

  19. Andersen RE, Arendt-Nielsen L, Madeleine P. Knee joint vibroarthrography of asymptomatic subjects during loaded flexion-extension movements. Med Biol Eng Comput. 2018;56(12):2301–12. https://doi.org/10.1007/s11517-018-1856-6.

    Article  PubMed  Google Scholar 

  20. Bączkowicz D, Kręcisz K, Borysiuk Z. Analysis of patellofemoral arthrokinematic motion quality in open and closed kinetic chains using vibroarthrography. BMC Musculoskelet Disord. 2019;20(1):48. https://doi.org/10.1186/s12891-019-2429-z.

    Article  PubMed  PubMed Central  Google Scholar 

  21. DeFrate LE, Kim-Wang SY, Englander ZA, McNulty AL. Osteoarthritis year in review 2018: mechanics. Osteoarthr Cartil. 2019;27(3):392–400. https://doi.org/10.1016/j.joca.2018.12.011.

    Article  CAS  PubMed  Google Scholar 

  22. Steinkamp LA, Dillingham MF, Markel MD, Hill JA. Kaufman KR biomechanical considerations in patellofemoral joint rehabilitation. Am J Sports Med. 1993;21(3):438–44. https://doi.org/10.1177/036354659302100319.

    Article  CAS  PubMed  Google Scholar 

  23. Cohen Z, Roglic H, Grelsamer RP, Henry JH, Levine WN, Mow VC, et al. Patellofemoral stresses during open and closed kinetic chain exercises. Am J Sports Med. 2001;29(4):480–7. https://doi.org/10.1177/03635465010290041701.

    Article  CAS  PubMed  Google Scholar 

  24. Besier TF, Draper CE, Gold GE, Beaupré GS, Delp SL. Patellofemoral joint contact area increases with knee flexion and weight-bearing. J Orthop Res. 2005;23(2):345–50. https://doi.org/10.1016/j.orthres.2004.08.003.

    Article  Google Scholar 

  25. Lorenz A, Rothstock S, Bobrowitsch E, Beck A, Gruhler A, Ipach I, et al. Cartilage surface characterization by frictional dissipated energy during axially loaded knee flexion—an in vitro sheep model. J Biomech. 2013;46(8):1427–32. https://doi.org/10.1016/j.jbiomech.2013.03.009.

    Article  PubMed  Google Scholar 

  26. Salem GJ, Powers CM. Patellofemoral joint kinetics during squatting in collegiate women athletes. Clin Biomech (Bristol, Avon). 2001;16(5):424–30.

    Article  CAS  Google Scholar 

  27. Whyte EF, Moran K, Shortt CP, Marshall B. The influence of reduced hamstring length on patellofemoral joint stress during squatting in healthy male adults. Gait Posture. 2010;31(1):47–51. https://doi.org/10.1016/j.gaitpost.2009.08.243.

    Article  PubMed  Google Scholar 

  28. Walter C, Leichtle U, Lorenz A, Mittag F, Wülker N, Müller O, et al. Dissipated energy as a method to characterize the cartilage damage in large animal joints: an in vitro testing model. Med Eng Phys. 2013;35(9):1251–5. https://doi.org/10.1016/j.medengphy.2013.01.002.

    Article  PubMed  Google Scholar 

  29. Levin S, de Solórzano SL, Scarr G. The significance of closed kinematic chains to biological movement and dynamic stability. J Bodyw Mov Ther. 2017;21(3):664–72. https://doi.org/10.1016/j.jbmt.2017.03.012.

    Article  PubMed  Google Scholar 

  30. Adouni M, Shirazi-Adl A. Knee joint biomechanics in closed-kinetic-chain exercise. Comput Methods Biomech Biomed Engin. 2009;12(6):661–70. https://doi.org/10.1080/10255840902828375.

    Article  CAS  PubMed  Google Scholar 

  31. Escamilla RF, Zheng N, Macleod TD, Edwards WB, Hreljac A, Fleisig GS, et al. Patellofemoral joint force and stress between a short-and long-step forward lunge. J Orthop Sports Phys Ther. 2008;38(11):681–90. https://doi.org/10.2519/jospt.2008.2694.

    Article  PubMed  Google Scholar 

  32. Powers CM, Ho KY, Chen YJ, Souza RB, Farrokhi S. Patellofemoral joint stress during weight­bearing and non-weight­bearing quadriceps exercises. J Orthop Sports Phys Ther. 2014;44(5):320–7. https://doi.org/10.2519/jospt.2014.4936.

    Article  PubMed  Google Scholar 

  33. Eliassen W, Saeterbakken AH, van den Tillaar R. Comparison of bilateral and unilateral squat exercises on barbell kinematics and muscle activation. Int J Sports Phys Ther. 2018;13(5):871–81.

    Article  Google Scholar 

  34. Hartmann H, Wirth K, Klusemann M. Analysis of the load on the knee joint and vertebral column with changes in squatting depth and weight load. Sports Med. 2013;43(10):993–1008. https://doi.org/10.1007/s40279-013-0073-6.

  35. Winckers AN, Mackenbach JD, Compernolle S, Nicolaou M, van der Ploeg HP, Brug J, et al. Educational differences in the validity of self-reported physical activity. BMC Public Health. 2015;15:1299. https://doi.org/10.1186/s12889-015-2656-7.

    Article  PubMed  PubMed Central  Google Scholar 

  36. Jakše B, Jakše B, Pinter S, Pajek J, Mis NF. Characteristics of slovenian adults in community-based whole-food plant-based lifestyle program. J Nutr Metab. 2020;2020:6950530. https://doi.org/10.1155/2020/6950530.

    Article  PubMed  PubMed Central  Google Scholar 

  37. Bączkowicz D, Majorczyk E. Joint motion quality in chondromalacia progression assessed by vibroacoustic signal analysis. PM&R. 2016;8(11):1065–71. https://doi.org/10.1016/j.pmrj.2016.03.012.

    Article  Google Scholar 

  38. Bączkowicz D, Majorczyk E. Joint motion quality in vibroacoustic signal analysis for patients with patellofemoral joint disorders. BMC Musculoskelet Disord. 2014;15:426. https://doi.org/10.1186/1471-2474-15-426.

    Article  PubMed  PubMed Central  Google Scholar 

  39. Rangayyan RM, Wu Y. Analysis of vibroarthrographic signals with features related to signal variability and radial-basis functions. Ann Biomed Eng. 2009;37:156–63. https://doi.org/10.1007/s10439-008-9601-1.

    Article  PubMed  Google Scholar 

  40. Bączkowicz D, Falkowski K, Majorczyk E. Assessment of relationships between joint motion quality and postural control in patients with chronic ankle joint instability. J Orthop Sport Phys Ther. 2017;47:570–7. https://doi.org/10.2519/jospt.2017.6836.

    Article  Google Scholar 

  41. Wallace DA, Salem GJ, Salinas R, Powers CM. Patellofemoral joint kinetics while squatting with and without an external load. J Orthop Sports Phys Ther. 2002;32(4):141–8. https://doi.org/10.2519/jospt.2002.32.4.141.

    Article  PubMed  Google Scholar 

  42. Ateshian GA, Hung CT. Patellofemoral joint biomechanics and tissue engineering. Clin Orthop Relat Res. 2005;436:81–90.

    Article  Google Scholar 

  43. Mabuchi K, Ujihira M, Sasada T. Influence of loading duration on the start-up friction in synovial joints: measurements using a robotic system. Clin Biomech (Bristol, Avon). 1998;13(7):492–4.

    Article  Google Scholar 

  44. Lizhang J, Fisher J, Jin Z. The effect of contact stress on cartilage friction, deformation and wear. Proc Inst Mech Eng H. 2011;225(5):461–75. https://doi.org/10.1177/2041303310392626.

    Article  CAS  PubMed  Google Scholar 

  45. Bączkowicz D, Skiba G, Szmajda M, Vařeka I, Falkowski K, Laudner K. Effects of viscosupplementation on quality of knee joint arthrokinematic motion analyzed by vibroarthrography. Cartilage. 2019;1947603519847737. https://doi.org/10.1177/1947603519847737.

  46. Singh N. Synovial joints and lubrication mechanisms. Int J Comput Appl Math. 2017;12(1):23–33.

    Google Scholar 

  47. Mansour J. Biomechanics of cartilage. In: Oatis CA, editor. Kinesiology: The mechanics and pathomechanics of human movement, vol. 68. Bristol: Lippincott Williams and Wilkins; 2009. p. 77.

  48. Katta J, Jin Z, Ingham E, Fisher J. Effect of nominal stress on the long term friction, deformation and wear of native and glycosaminoglycan deficient articular cartilage. Osteoarthr Cartil. 2009;17(5):662–8. https://doi.org/10.1016/j.joca.2008.10.008.

    Article  CAS  PubMed  Google Scholar 

  49. Ladly KO, Frank CB, Bell GD, Zhang YT, Rangayyan RM. The effect of external loads and cyclic loading on normal patellofemoral joint signals. Def Sci J. 1993;43(3):201–10.

    Article  Google Scholar 

  50. Befrui N, Elsner J, Flesser A, Huvanandana J, Jarrousse O, Le T.N. Vibroarthrography for early detection of knee osteoarthritis using normalized frequency features. Med Biol Eng Comput 2018;56(8):1499–1514. doi:https://doi.org/10.1007/s11517-018-1785-4.

Download references

Acknowledgments

We would like to thank all of the subjects who participated in the study. We express our special gratitude to Mr. Krzysztof Kręcisz for technical assistance.

Funding

No funding was received for this project.

Author information

Authors and Affiliations

Authors

Contributions

EO and DB contributed to the formulation of concepts and design of the study, analysis and interpretation of the data and writing of the manuscript. KL, NS and DP introduced substantial revisions in the manuscript which were accepted by EO and DB. All authors read and approved the manuscript and have given consent for the submission of the final article.

Corresponding author

Correspondence to Dawid Bączkowicz.

Ethics declarations

Ethics approval and consent to participate

The project was approved by the Opole Voivodeship Ethics Committee (ethical approval code No. 202/06.06.2013). Before testing, all subjects provided written informed consent to participate in the study and to have their results analyzed.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ołowiana, E., Selkow, N., Laudner, K. et al. Vibroarthrographic analysis of patellofemoral joint arthrokinematics during squats with increasing external loads. BMC Sports Sci Med Rehabil 12, 51 (2020). https://doi.org/10.1186/s13102-020-00201-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13102-020-00201-z

Keywords